Inductive Sensors

Inductive proximity switch in 12mm housing for monitoring slides, flaps and other metal parts.
- Switching distance 4mm, flush mountable front
- Metal housing M12x1mm with two nuts
- Length 61mm
- Operating voltage 10 – 30VDC
- Max. switching current 200mA, NO
- Built-in thermal fuse 70°C
- Connection cable: 2m, shielded
- Increased interference protection
- IP safety class 67
- LED switch indicator
- Approved for application in ATEX zone 22
Art. 4005

Inductive proximity switch in 12mm housing for monitoring slides, flaps or other metal parts.
- Switching distance 4mm, flush mountable front
- Metal housing M12x1mm with two nuts
- Length 61mm
- Operating voltage 10 – 30VDC
- Max. switching current 200mA, NC
- Connection cable: 2m, shielded
- IP safety class 67
- LED switch indicator
- Approved for application in ATEX zone 22
Art. 4006

Inductive proximity switch in 12mm housing for monitoring slides, flaps and other metal parts.
- Switching distance 4mm, flush mountable front
- Metal housing M12x1mm with two nuts
- Length 65mm
- Operating voltage 10 – 30VDC
- Max. switching current 200mA, NO and NC
- With connector M12x1
- Increased interference protection
- IP safety class 65, 66, 67 (depending on connector)
- LED switch indicator
Art. 3060011

Inductive proximity switch in 12mm housing for monitoring slides, flaps and other metal parts.
- Short switching distance 2mm, flush mountable front
- Metal housing M12x1mm with two nuts
- Length 65mm
- Operating voltage 10 – 30VDC
- Max. switching current 200mA, NO and NC
- With connector M12x1
- Increased interference protection
- IP safety class 65, 66, 67 (depending on connector)
- LED switch indicator
Art. 3060010
Accessories:
- Art. 3080034 Connection cable with M12 socket and open ends, 3m

Inductive proximity switch in 18mm housing for monitoring slides, flaps or other metallic parts.
- Switching distance 8mm, flush mountable front
- Metal housing M18x1mm with two nuts
- Length 63mm
- Operating voltage 10 – 30VDC
- Max. switching current 200mA, NO and NC
- Built-in thermal fuse 70°C
- Connection cable: 2m, shielded
- Increased interference protection
- IP safety class 67
- LED switch indicator
- Approved for application in ATEX zone 22
Art. 4023
Accessories:
- Art. 3080014 Speed detector Roto for 18 and 30mm sensors

Inductive proximity switch in 18mm housing for monitoring slides, flaps and other metal parts.
- Switching distance 8mm, flush mountable front
- Metal housing M18x1mm with two nuts
- Length 70mm
- Operating voltage 10 – 30VDC
- Max. switching current 200mA, NO and NC
- Built-in thermal fuse 70°C
- With connector M12x1
- Increased interference protection
- IP safety class 65, 66, 67 (depending on connector)
- LED switch indicator
Art. 3060008
Accessories:
- Art. 3080014 Speed detector Roto for 18 and 30mm sensors

Inductive proximity switch in 30mm housing for monitoring slides, flaps or other metallic parts.
- Switching distance 15mm, flush mountable front
- Metal housing M30x1.5mm with two nuts
- Length 43mm
- Operating voltage 10 – 30VDC
- Max. switching current 200mA, NO and NC
- Built-in thermal fuse 70°C
- Connection cable: 2m, shielded
- Increased interference protection
- IP safety class 67
- LED switch indicator
- Approved for application in ATEX zone 22
Art. 3060002
Accessories:
- Art. 3080014 Speed detector Roto for 18 and 30mm sensors

Inductive proximity switch in 30mm housing for monitoring slides, flaps or other metallic parts.
- Switching distance 15mm, flush mountable front
- Metal housing M30x1.5mm with two nuts
- Length 43mm
- Operating voltage 10 – 30VDC
- Max. switching current 200mA, NO and NC
- With connector M12x1
- Increased interference protection
- IP safety class 65, 66, 67 (depending on connector)
- LED switch indicator
Art. 3060003
Accessories:
- Art. 3080014 Speed detector Roto for 18 and 30mm sensors

Inductive proximity switch with switching distance 20 - 80mm, suitable for e.g. misalignment monitoring of elevators or other actuators.
- Switching distance adjustable 20 - 80mm
- Plastic housing 80x80mm
- Operating voltage 10 – 35VDC
- Max. switching current 200mA, NO and NC
- Temperature range: -20°C to +60°C
- Built-in thermal fuse 70°C
- Connection cable: 2m, shielded
- IP safety class 67
- LED switch indicator
- Approved for application in ATEX zone 22 with art. 3080007
Art. 3060005
Accessories:
- Art. 3714 Sight glass separation plate with viton O-ring
- Art. 3080007 Sensor mounting bracket ASIQ80
We always have various special sensors in stock. For an individual consulting please contact Agromatic.